Moccamaster models

From ivc wiki
Revision as of 21:51, 23 September 2023 by Ivc (talk | contribs) (→‎Model list)
Jump to navigationJump to search

Model numbers

What the letters mean:

H Rectangular body column, single-setting hotplate (Europe only)
K Rectangular body column, dual-setting hotplate (2-5 cups use 3/4 circle (80C/175F) / 6-10 cups use full circle (85C/185F) to activate both heating elements)
B Filter holder platform
CD Cylindrical body column, dual-setting hotplate (2-5 cups use 3/4 circle / 6-10 cups use full circle to activate both heating elements)
G Automatic drip-stop when removing carafe
Non-G Manual adjust drip-stop on basket (closed / 2-5 cups use half-open for limited flow thru rate / 6-10 cups use fully-open for normal flow thru rate)
V Volume / flow control, paired with corresponding hotplate temperature level (2-6 cups use half-carafe for longer brew time and temperature stability / 7-10 cups use full-carafe for normal brew time and temperature)
T Thermo steel carafe
Non-T Glass carafe
S Smaller, 8-cups, manual adjust drip-stop, single setting hotplate, auto-off
AO Automatically turn off system / hotplate after 40(EU)-100 min

Model list

Different models, old and new:

* Popular models

Model Carafe Capacity Hotplate Housing Brew control Drip-stop Auto-off system / hotplate
H glass 10 cups / 1.25 L / 40 oz single setting rectangular none none manual switch
HB glass 10 cups / 1.25 L / 40 oz single setting rectangular brew flow lever, 2-5 cups / 6-10 cups manual close lever manual switch
HB AO glass 10 cups / 1.25 L / 40 oz single setting rectangular brew flow lever, 2-5 cups / 6-10 cups manual close lever automatic, 40-100 min
HBG glass 10 cups / 1.25 L / 40 oz single setting rectangular none automatic close manual switch
K glass 10 cups / 1.25 L / 40 oz 2 settings rectangular none none manual switch
KB glass 10 cups / 1.25 L / 40 oz 2 settings rectangular brew flow lever, 2-5 cups / 6-10 cups manual close lever manual switch
* KB AO / MANUAL glass 10 cups / 1.25 L / 40 oz 2 settings rectangular brew flow lever, 2-5 cups / 6-10 cups manual close lever automatic, 40-100 min
KBG glass 10 cups / 1.25 L / 40 oz 2 settings rectangular none automatic close manual switch
* KBG AO / AUTOMATIC glass 10 cups / 1.25 L / 40 oz 2 settings rectangular none automatic close automatic, 40-100 min
* KBGV / KBG SELECT / OPTIO glass 10 cups / 1.25 L / 40 oz 2 settings, paired with flow switch rectangular brew flow switch, 2-6 cups / 7-10 cups automatic close automatic, 40-100 min
KBS glass 8 cups / 1 L / 32 oz single setting rectangular brew flow lever, 2-5 cups / 6-10 cups manual close lever automatic, 40-100 min
KBT / MANUAL THERMO steel 10 cups / 1.25 L / 40 oz none rectangular brew flow lever, 2-5 cups / 6-10 cups manual close lever manual switch
* KBGT / AUTOMATIC THERMO steel 10 cups / 1.25 L / 40 oz none rectangular none automatic close manual switch
KBTS steel 8 cups / 1 L / 32 oz none rectangular brew flow lever, 2-5 cups / 6-10 cups manual close lever manual switch
CD (Europe only) glass 10 cups / 1.25 L / 40 oz 2 settings cylindrical none none manual switch
CD AO (Europe only) glass 10 cups / 1.25 L / 40 oz 2 settings cylindrical none none automatic, 40-100 min
CDG glass 10 cups / 1.25 L / 40 oz 2 settings cylindrical none automatic close manual switch
CDK glass 10 cups / 1.25 L / 40 oz single setting cylindrical none none manual switch
CD GRAND glass 14 cups / 1.8 L / 60 oz 2 settings cylindrical none manual pull-out manual switch
CDT / THERMO steel 10 cups / 1.25 L / 40 oz none cylindrical brew flow lever, 2-5 cups / 6-10 cups manual close lever manual switch
CDT GRAND steel 14 cups / 1.8 L / 60 oz none cylindrical none manual pull-out manual switch
CDGT / AUTOMATIC THERMO steel 10 cups / 1.25 L / 40 oz none cylindrical none automatic close manual switch
CDGT AO steel 10 cups / 1.25 L / 40 oz none cylindrical none automatic close automatic, 40-100 min
ONE-CUP none 1 cup / 0.33 L / 10 oz none rectangular none none manual switch

- Model names with an "S" at the end, i.e. "AUTOMATIC S", means indicator for descaling - There are no "T" / thermo models with AO/AUTOFF since there is no hotplate and the float switch will turn off the system entirely

References