Difference between revisions of "HP ProLiant DL380 G5 BIOS Updates"

From ivc wiki
Jump to navigationJump to search
 
(30 intermediate revisions by the same user not shown)
Line 1: Line 1:
The DL380 G5 BIOS updates are hard to get hold of, so get them below instead.
The DL380 G5 BIOS updates are hard to get hold of, so get them below instead.


== Flash utility ==
* Model: HP ProLiant DL380 G5 (Gen. 5) U2 rack server
Use the USB Flash Key tool to make a USB flash drive as a base.
* Product code: P56
* Available: 2006 to 2011
* Stock BIOS (mine): 2010.10.25
* Stock iLON 2 firmware (mine): 2.05
* Stock Smart Array P400 firmware: 7.22


* [Flash tool]
== ROMPaq flash utility ==
 
This guide uses the 2011.05.02 bios bundle as a base. Extract this .exe-bundle using WinRar (right-click, extract) and use the HPQUSB.exe tool in the "ROMPaq USB Key" folder to make a USB flash drive.
 
Download bundle:
 
* [http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_970dc8e46003491394f328f1ca&swEnvOid=4074 ROMPaq Firmware Upgrade for HP ProLiant DL380 G5 (P56) Servers] - bios 2011.05.02 and tools - SP53328.exe
* [http://beta.ivc.no/dl380_g5/SP53328.exe Local mirror of 2011.05.02 bios bundle SP53328.exe]


== BIOS updates ==
== BIOS updates ==
Line 10: Line 21:
The following list are all the BIOS updates as of February 2017 for this rack server.
The following list are all the BIOS updates as of February 2017 for this rack server.


* 08/16/2015
Download:
 
* '''[http://beta.ivc.no/dl380_g5/dl380_g5_bios_updates.rar Download all BIOS updates and USB flash utility] - these are copied and copiled directly from the official HP DL380 G5 download page'''
 
Includes the following versions ([http://h20566.www2.hpe.com/hpsc/swd/public/detail?sp4ts.oid=1121413&swItemId=MTX_9f733f71a7ae4e399b2ed4f5dd&swEnvOid=4064# HP direct link]):


Download:
* BIOS 2015.08.16
* BIOS 2011.05.02
* BIOS 2010.10.25
* BIOS 2010.04.26
* BIOS 2009.07.10
* BIOS 2009.05.18
* BIOS 2008.11.01
* BIOS 2008.09.29
* BIOS 2008.08.03
* BIOS 2008.06.25
* BIOS 2008.01.09
* BIOS 2008.01.24
* BIOS 2007.11.13
* BIOS 2007.10.04
* BIOS 2007.08.21
* BIOS 2007.06.28
* BIOS 2007.05.01
* BIOS 2007.04.06
* BIOS 2006.12.28 - Not available
* BIOS 2006.11.08 - Not available
* BIOS 2006.09.18 - Not available
* BIOS 2006.06.13 - Not available
* BIOS 2006.05.30 - Not available


* '''[Download all BIOS updates]'''
To use any of the following updates, make the above flash drive and replace the CPQP5602.XXX file on the drive with the bios file you want to flash. Insert the USB drive and reboot into the ROMPAQ.exe flash tool.


To use any of the following updates, make the above flash drive and replace the P56.XXX file on the drive with the bios file you want to flash. Insert the USB drive and reboot into the ROMPAQ.exe flash tool. You can use iLO2 Remote Console in Firefox to connect to the server and perform the update.
You can use iLO2 Remote Console in Firefox to connect to the server and view/perform the update, you still need physical access unless you make an ISO of the USB drive and mount it virtually in iLO2.


[[Image:HP_ProLiant_Flash_Tool.png|300px]]
[[Image:HP_ProLiant_Flash_Tool.png|300px]]


== iLO2 firmware updates ==


Download all updates:


== iLO2 firmware updates ==
* '''[http://beta.ivc.no/dl380_g5/ilon2_firmware_updates.rar iLON 2 Firmware updates download] - package of all firmwares as of February 2017, directly downloaded and compiled from HP'''


To update iLO2, configure Java (in the Java Control Panel) to use the following TLS 1.0 settings, open Firefox, go to Administration -> iLO2 Firmware and pick the firmware file. Click 'Send firmware image' and the progress bar should show all the passes for retreiving, verifing and flashing.
To update iLO2, configure Java (in the Java Control Panel) to use the following TLS 1.0 settings, open Firefox, go to Administration -> iLO2 Firmware and pick the firmware file. Click 'Send firmware image' and the progress bar should show all the passes for retreiving, verifing and flashing.
Line 28: Line 67:
[[Image:HP_ProLiant_iLO2_Java_Settings.png|200px]] [[Image:HP_ProLiant_iLO2_Firmware.png|300px]]  
[[Image:HP_ProLiant_iLO2_Java_Settings.png|200px]] [[Image:HP_ProLiant_iLO2_Firmware.png|300px]]  


Includes the following versions:
* iLON 2 v2.29
* iLON 2 v2.27
* iLON 2 v2.25
* iLON 2 v2.23
* iLON 2 v2.22
* iLON 2 v2.20
* iLON 2 v2.15
* iLON 2 v2.12
* iLON 2 v2.09
* iLON 2 v2.07
* iLON 2 v2.06
* iLON 2 v2.05
* iLON 2 v2.01
* iLON 2 v1.82
* iLON 2 v1.81
* iLON 2 v1.80
* iLON 2 v1.79
* iLON 2 v1.78
* iLON 2 v1.77
* iLON 2 v1.70
* iLON 2 v1.61
* iLON 2 v1.60
== HP Smart Array P400 firmware  ==
[[Image:HP_ProLiant_Smart_Array_P400.png|240px]] [[Image:HP_ProLiant_Smart_Update_Firmware.png|300px]]
Download all firmware updates:
* '''[http://beta.ivc.no/dl380_g5/smart_array_p400_firmware_updates.rar HP Smart Array P400 firmware updates] - downloaded and compiled directly from the [http://h20564.www2.hpe.com/hpsc/swd/public/detail?sp4ts.oid=1121413&swItemId=MTX_bc1046a3541a46389b7fa2d755&swEnvOid=4025 HP Smart Array P400 download page]'''
The easiest way to get the update applied is either live on a Linux system or preferrably using a bootable USB drive. Download the final Smart Update Firmware DVD 10.10 2012.06.04 and create a drive using [http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_948972949139480992fcb5b558 HP USB Key 2.0], then copy the Smart Array P400 .scexe-file into the /hp/swpackages/ directory.
The Smart Update Firmware DVD also includes [http://h50146.www5.hpe.com/products/software/oe/linux/mainstream/support/doc/general/hw_setup/suf/files/v1010--cdcontent-fw.htm a list of other firmware updates].
* [http://h20564.www2.hpe.com/hpsc/swd/public/detail?sp4ts.oid=1121413&swItemId=MTX_9ed665a89aba447d925937f38b&swEnvOid=4115 Smart Update Firmware DVD 10.10 2012.06.04] - firmware-10.10-0.zip, 1.4 GB
Included versions:
* Firmware v7.24
* Firmware v7.22
* Firmware v7.18B
* Firmware v7.18
* Firmware v7.08
* Firmware v6.86
* Firmware v5.26C
* Firmware v5.26B
* Firmware v5.26
* Firmware v5.22
* Firmware v5.20
* Firmware v4.12
* Firmware v4.06
* Firmware v2.10
* Firmware v2.08
== References ==


* 2.29
* [http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1121413&lang=en&cc=us Official HP driver support page]
* [http://serverfault.com/questions/793011/update-all-firmware-on-hp-dl380-g5-server Update all firmware on HP DL380 G5 server]

Latest revision as of 00:20, 22 February 2017

The DL380 G5 BIOS updates are hard to get hold of, so get them below instead.

  • Model: HP ProLiant DL380 G5 (Gen. 5) U2 rack server
  • Product code: P56
  • Available: 2006 to 2011
  • Stock BIOS (mine): 2010.10.25
  • Stock iLON 2 firmware (mine): 2.05
  • Stock Smart Array P400 firmware: 7.22

ROMPaq flash utility

This guide uses the 2011.05.02 bios bundle as a base. Extract this .exe-bundle using WinRar (right-click, extract) and use the HPQUSB.exe tool in the "ROMPaq USB Key" folder to make a USB flash drive.

Download bundle:

BIOS updates

The following list are all the BIOS updates as of February 2017 for this rack server.

Download:

Includes the following versions (HP direct link):

  • BIOS 2015.08.16
  • BIOS 2011.05.02
  • BIOS 2010.10.25
  • BIOS 2010.04.26
  • BIOS 2009.07.10
  • BIOS 2009.05.18
  • BIOS 2008.11.01
  • BIOS 2008.09.29
  • BIOS 2008.08.03
  • BIOS 2008.06.25
  • BIOS 2008.01.09
  • BIOS 2008.01.24
  • BIOS 2007.11.13
  • BIOS 2007.10.04
  • BIOS 2007.08.21
  • BIOS 2007.06.28
  • BIOS 2007.05.01
  • BIOS 2007.04.06
  • BIOS 2006.12.28 - Not available
  • BIOS 2006.11.08 - Not available
  • BIOS 2006.09.18 - Not available
  • BIOS 2006.06.13 - Not available
  • BIOS 2006.05.30 - Not available

To use any of the following updates, make the above flash drive and replace the CPQP5602.XXX file on the drive with the bios file you want to flash. Insert the USB drive and reboot into the ROMPAQ.exe flash tool.

You can use iLO2 Remote Console in Firefox to connect to the server and view/perform the update, you still need physical access unless you make an ISO of the USB drive and mount it virtually in iLO2.

HP ProLiant Flash Tool.png

iLO2 firmware updates

Download all updates:

To update iLO2, configure Java (in the Java Control Panel) to use the following TLS 1.0 settings, open Firefox, go to Administration -> iLO2 Firmware and pick the firmware file. Click 'Send firmware image' and the progress bar should show all the passes for retreiving, verifing and flashing.

HP ProLiant iLO2 Java Settings.png HP ProLiant iLO2 Firmware.png

Includes the following versions:

  • iLON 2 v2.29
  • iLON 2 v2.27
  • iLON 2 v2.25
  • iLON 2 v2.23
  • iLON 2 v2.22
  • iLON 2 v2.20
  • iLON 2 v2.15
  • iLON 2 v2.12
  • iLON 2 v2.09
  • iLON 2 v2.07
  • iLON 2 v2.06
  • iLON 2 v2.05
  • iLON 2 v2.01
  • iLON 2 v1.82
  • iLON 2 v1.81
  • iLON 2 v1.80
  • iLON 2 v1.79
  • iLON 2 v1.78
  • iLON 2 v1.77
  • iLON 2 v1.70
  • iLON 2 v1.61
  • iLON 2 v1.60

HP Smart Array P400 firmware

HP ProLiant Smart Array P400.png HP ProLiant Smart Update Firmware.png

Download all firmware updates:

The easiest way to get the update applied is either live on a Linux system or preferrably using a bootable USB drive. Download the final Smart Update Firmware DVD 10.10 2012.06.04 and create a drive using HP USB Key 2.0, then copy the Smart Array P400 .scexe-file into the /hp/swpackages/ directory.

The Smart Update Firmware DVD also includes a list of other firmware updates.

Included versions:

  • Firmware v7.24
  • Firmware v7.22
  • Firmware v7.18B
  • Firmware v7.18
  • Firmware v7.08
  • Firmware v6.86
  • Firmware v5.26C
  • Firmware v5.26B
  • Firmware v5.26
  • Firmware v5.22
  • Firmware v5.20
  • Firmware v4.12
  • Firmware v4.06
  • Firmware v2.10
  • Firmware v2.08

References